Get in touch

Hydropower: An old technology with a new role 

Hydropower is among humanity’s oldest energy technologies, and it is finding a new role. As wind and solar grow, pumped storage can hold surplus electricity and release it for hours when it is needed. The UK is returning to large-scale schemes after years of slow investment. But the same water that drives the turbines can also cause disaster. Dam breaches, burst penstocks, and catastrophic machinery failures, as have occurred around the world, show what can go wrong. This article looks at how hydropower works, why it matters again, what it costs the environment, and how safe-by-design thinking helps manage the risks across a scheme’s decades-long life..

Introduction

Long before electricity was generated, people were harnessing the power of moving water. Water wheels were used to grind grain in ancient Greece more than 2,000 years ago, with water later powering mills and machinery across the world. The development of turbines and electrical generators transformed this established principle into modern hydropower. 

The principle remains remarkably simple: water flowing from a higher level to a lower one drives a turbine connected to a generator. The difference in height is known as the head. Together, the available head and the rate at which water flows through the turbine determine how much power a scheme can produce. 

At commercial scale, however, hydropower involves far more than a turbine in a river. Projects can include dams, reservoirs, tunnels, high-pressure pipelines, underground powerhouses, and extensive electrical infrastructure. Some schemes store and control enormous volumes of water, with infrastructure designed to operate for many decades. While these arrangements provide valuable electricity generation and storage capabilities, they also introduce significant hazards extending well beyond the generating plant itself. 

Medieval illustration of a saddled donkey beside a watermill from The Bodleian Bestiary (MS. Bodl. 764, folio 44r), c. 1226–1250.

FROM RIVERS TO RESERVOIRS 

Hydropower schemes generally fall into three broad types. 

  • Run-of-the-river schemes divert water from a river through a channel, tunnel, or pipeline to a turbine before returning it downstream. With little or no capacity to store water, generation depends largely on river flow. These schemes are not necessarily small: the available head and flow determine their potential scale. 
  • Reservoir or storage schemes retain water behind a dam, allowing it to be released through turbines when electricity is required. This provides greater control over when electricity is generated, although the amount of energy available ultimately depends on water inflows and reservoir capacity. 
  • Pumped storage schemes use two reservoirs at different elevations to store energy. Electricity is used to pump water to the upper reservoir, typically when demand is low or renewable generation is plentiful. When electricity is needed, the water is released through turbines to generate power. Although around 20% to 30% more energy is consumed in pumping than is recovered during generation due to inherent losses, pumped storage provides a means of storing electricity at scale and supplying it when needed. 

Some projects combine features of more than one type. The arrangement, location, and operating characteristics of each scheme influence both its benefits and the hazards that need to be managed.

Emosson Dam and hydroelectric/pumped storage scheme in the Swiss Alps

WHY HYDROPOWER MATTERS (AGAIN!) 

Hydropower is a well-established renewable energy technology that provides low-carbon electricity, reducing reliance on fossil fuels and the associated greenhouse gas emissions. Where suitable water resources are available, reservoir schemes can provide a dependable source of power and respond rapidly to changes in demand. 

Pumped storage has a different and increasingly important role in the energy transition. As electricity generation becomes more dependent on variable renewable sources such as wind and solar, the ability to store energy and release it when needed becomes increasingly valuable. Pumped storage achieves this by using surplus electricity to move water uphill, then releasing it through turbines when demand rises or renewable generation falls. Some schemes can supply electricity for many hours, helping to reduce reliance on fossil fuel generation during these periods. Its value lies in making stored energy available when it is most needed. 

The UK developed numerous major hydropower and pumped storage schemes during the twentieth century, but investment in new large-scale projects subsequently slowed. Long development times, high upfront costs, and uncertainty over future revenues have made new schemes difficult to finance. With the growing need for long-duration energy storage, however, interest is returning. 

The UK Government has introduced a new investment framework, administered by Ofgem, to support the development of long-duration electricity storage (LDES), including pumped storage hydropower. Known as the ‘cap and floor’ scheme, it aims to provide greater revenue certainty for investors, potentially unlocking a new generation of large-scale storage projects.

Foyers power station on Loch Ness – the original plant was built in 1896, Scotland’s earliest large-scale hydroelectric development

THE TRADE-OFFS

Although carbon emissions during hydropower plant operation are low, reservoirs can release methane from decaying organic matter, so lifecycle emissions vary from scheme to scheme. Furthermore, its development can have significant environmental and social impacts. Creating reservoirs can flood substantial areas of land, altering landscapes, affecting habitats and communities, and displacing existing land uses. Dams and water diversions can also change river flows, sediment movement, water quality, and fish migration. Construction may involve extensive excavation, tunnelling, access roads, and the movement of large quantities of materials. 

The nature and scale of these impacts depend heavily on the location and design of the scheme. For example, a pumped storage project using existing reservoirs will have a much lower environmental footprint than one requiring new dams and reservoirs. In each case, the benefits of renewable generation or energy storage need to be weighed against the environmental and social consequences of developing and operating the infrastructure.

WHERE THE SAFETY RISKS ARISE 

Uncontrolled release of water 

The most far-reaching hazard associated with hydropower is an uncontrolled release of water. Failure of a dam or embankment, reservoir overtopping, or failure of a water conveyance system can cause rapid flooding, with potentially devastating consequences extending far beyond the site. In 2005, the upper reservoir at the Taum Sauk pumped storage plant in the United States was overtopped and breached following failures in water level measurement and protection arrangements, demonstrating the importance of reliable monitoring and safeguards. 

Failed dam at the Taum Sauk pumped storage plant in the United States, 2005, resulting in significant environmental, financial, and regulatory consequences (fortunately, no lives were lost)

Pressure and flow within the scheme 

Water also presents significant hazards within the scheme. Penstocks, tunnels, and valves can contain large volumes of water under substantial pressure. A rupture or unexpected release can flood a powerhouse, damage equipment, and endanger personnel. Rapid changes in flow, including those associated with starting, stopping, or equipment faults, can also generate damaging pressure surges (often called water hammer). Even during normal operation, sudden changes in downstream flows can cause river levels to rise rapidly and with little warning, endangering people downstream.

Ground conditions and natural events 

Ground conditions and natural events can affect the long-term integrity of dams, foundations, reservoir slopes, and underground works. Seepage, erosion, and ground movement may develop gradually, while extreme rainfall, flooding, and seismic events can place additional demands on structures and protective systems. Understanding these hazards requires consideration of both the original design conditions and how the asset and its environment may change over time. 

Machinery and powerhouse failure 

Within the powerhouse, large rotating machines introduce significant mechanical hazards. The 2009 major incident at Russia’s Sayano-Shushenskaya hydropower station demonstrates how severe machinery failure can escalate. Excessive vibration contributed to fatigue failure of the mountings on one of its turbines, resulting in the turbine assembly being displaced and pressurised water flooding the powerhouse. Seventy-five people were killed. 

This event highlights the importance of understanding operating limits, monitoring equipment condition, investigating developing faults, and ensuring that appropriate protective systems are in place.

Sayano-Shushenskaya hydropower incident in 2009, resulting in 75 fatalities 

Electricity and fire 

Electric shock, arc flash, and fire present further hazards during operation and maintenance. High-voltage equipment, large generators, and transformers hold substantial electrical energy, and a fault can release it suddenly as an arc flash, causing severe injury and damaging equipment. Insulating and lubricating oils, cabling, and generator windings can also fuel fires, which may be difficult to reach and fight in confined or underground powerhouses, so safe isolation procedures, fault protection, fire detection, and suppression systems are essential. 

Construction, commissioning and decommissioning 

Significant risks also arise during construction and commissioning. Large excavations, tunnelling, working near water, dam construction, and the initial filling of reservoirs each introduce distinct hazards. Design decisions must also consider how the completed asset will be safely inspected, maintained, repaired, and eventually decommissioned. 

DESIGNING FOR A SAFE LIFE 

Hydropower hazards cannot be understood by considering dams, water conveyance systems, turbines, and electrical equipment in isolation. Significant risks often arise from the interactions between water flows, ground conditions, structures, machinery, control systems, and the people who operate and maintain them. 

A safe-by-design approach begins at concept stage, when decisions about site selection, layout, and technology can eliminate hazards or reduce both their likelihood and their consequences. As the design develops, credible failure scenarios need to be assessed, and appropriate safeguards incorporated. These may include structural protection, pressure relief arrangements, reliable monitoring, and automatic protection systems to prevent abnormal conditions from escalating. 

Safety must also be considered throughout the asset’s operating life. Dams, tunnels, pipelines, and generating equipment require inspection, maintenance, and ongoing assessment as their condition and operating demands change. Designing for safe access, effective monitoring, and the ability to maintain or replace critical equipment helps ensure that risks remain controlled over the decades that hydropower infrastructure may operate. 

CONCLUSION

Hydropower is one of the oldest ways of harnessing renewable energy, yet its role in the modern electricity system continues to evolve. Alongside providing dependable low-carbon generation, pumped storage offers the flexibility and large-scale energy storage increasingly needed to support greater reliance on wind and solar power. 

Realising these benefits requires careful management of the significant hazards associated with large-scale hydropower infrastructure. From the containment and control of vast quantities of water to the integrity of complex mechanical and electrical systems, safety must be embedded in decisions throughout design, construction, operation, and eventual decommissioning. By applying safe-by-design principles and maintaining effective safeguards throughout the asset lifecycle, hydropower can continue to make a valuable contribution to a cleaner, more resilient energy system. 

RELATED CAIRN CONTENT

Electricity and the energy transition (Part 1) – Rewiring a net zero future
Electricity and the energy transition (Part 1) – Rewiring a net zero future
Defending the defenders: Climate-resilient infrastructure to deliver the energy transition
Defending the defenders: Climate-resilient infrastructure to deliver the energy transition

Contact Us

Want to discuss your requirements?
Get in touch

Jump to Top